Rinnai infinity 16 user manual
Refer to warning about hot water on page 16 for important safety information. The Infinity 16i controls the water tem- If freezing temperatures perature automatically.
Additional remote controllers are available to locate near the points of use, and give precise digital temperature control. Used correctly, the Infinity will supply hot water at the temperature selected, even when the water flow is varied, or when more than one tap is used.
The Rinnai Infinity 16i water heater can be operated with 1, 2, or 3 temperature controllers. The system will become active, the temperature will default to 40 C and the controller that turned the system on will have priority. The temperature setting on the controller will light up. Switching the system ON. When the system is turned ON the water temperature display will be lit. Page 13 The Digital Monitor will go out. If hot water taps are opened when the Rinnai Infinity is off, cold water will flow from the taps.
If the system is to be left off over the winter be sure to drain it down if there is a possibility of freezing temperatures. This is to ensure continued safety of the gas appliance. If you need a recommended service engineer contact Rinnai or your supplier. Care When the appliance casing, operation panel, and remote controls surfaces become dirty gently wipe them clean with a soft, damp cloth.
If a fault occurs, an error code will flash on the Digital Display if you have temperature controllers installed. This assists with diagnosing the fault, and may enable you to overcome a problem without a service call. Page 17 Troubleshooting without controllers If you have not installed temperature controllers and experience the following symptoms, please carry out the suggestions below.
If symptoms continue, please contact Rinnai for advice. Heater does not attempt Check the power is on at the heater. Page Restarting The Rinnai Water Heater If following the above procedure does not reset the heater switch it on and off at its main supply, and then go through these steps again.
If heater is still not working call your local service agent or Rinnai for assistance. Page Installation Instructions If the information in this manual is not followed exactly a fire or explosion could result. This manual must be read in its entirety before installing the appliance.
If you are unsure of any point contact Rinnai or your supplier. Page Uk Installation Instructions Please be sure that you are fully aware of your obligations and responsibilities under these regulations. In case of defective parts only use genuine Rinnai components for replacement failure to do so will invalidate any warranty.
Disposal Information: Under the laws and local regulations, this product must be disposed separately from house- hold waste. DO NOT install a damaged appliance before checking with your supplier.
Check that the appliance supplied is the correct gas type for the installation. Gas Control Unit 1. Thermal Fuse The thermal fuse is an electric link which must be intact for the unit to operate.
Heat exchangers damaged by scaling are not covered by the manufacturers guarantee. Guidelines are given below. If the local water exceeds these values the heater must be protected. Check pipe sizing required for the heater input. The heat input for the Infinity 16e is Check that the size of the gas meter and pipework will be sufficient for all appliances on the main. Sufficient gas must be available at the appliance if correct operation is to be expected.
An approved gas isolation valve must be fitted at the gas inlet. A union or release fitting should be installed after the isolation valve.
The appliance must be earthed. The appliance is suitable for VAC — 50hz mains only and all wiring must be carried out to the I. E regulations latest edition. The heater electrical supply must be provided with a fused 3A local isolator with a contact separation of 3mm minimum on all poles for servicing.
Observe polarity and ensure that wiring is correctly restrained. As long as electricity, water, and gas supplies are connected, hot water is available when hot water taps are open.
The water temperature may be limited to various maximum temperatures. This is particularly useful when the hot water unit is. The Infinity 16e is delivered with a preset temperature of 55 0 C. If required, the temperature limits can be changed by an authorised person. For further information, please contact Rinnai. When the hot water tap is off, no gas is used. This offers the following additional features:. Welcome to ManualMachine.
We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. Rinnai 16e User Manual Download for 1. You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add.
Get 1 for every time someone downloads your manual. Do you have a question about the Rinnai Infinity 16 or do you need help? Ask your question here. Provide a clear and comprehensive description of the issue and your question. The more detail you provide for your issue and question, the easier it will be for other Rinnai Infinity 16 owners to properly answer your question. View the manual for the Rinnai Infinity 16 here, for free. This manual is available in the following languages: English.